2024年5月11日发(作者:)

SINUMERIK 840D sl

Upgrade instructions

SINUMERIK Operate 4.7 SP3 for PCU 50.5 / IPC

2016-12-07

_________________________________________________________________________________________

SINUMERIK Operate 04.07.04.00 (internal version 04.07.04.00.016) for PCU 50.5 / IPC

_________________________________________________________________________________________

To install this software,

a PCU 50.5 with previously installed PCU Base Software Win7 V10.0 (or later)

a PCU 50.5 with previously installed PCU Base Software WinXP V1.4 HF9 (or later)

is required.

Important note for operation on PCU 50.5 Windows 7:

Before switching off the power supply of the PCU 50.5 / IPC, the system should be shut down using the Operate

softkey EXIT or using the Windows shutdown function, in the same way as with a PC with Windows 7. A UPS

should be used to provide protection against unexpected power failures.

The commissioning instructions for SINUMERIK Operate 4.7 SP2 and the PCU base software Win7 / WinXP, the

Equipment Manual Operator Components and the SINUMERIK operating instructions Operate 4.7 SP2 apply

accordingly. In addition, the general conditions published for the CNC software 4.7 SP4 must be observed.

SINUMERIK Operate 4.7 SP4 is only released for operating SINUMERIK 840D sl NCU7x0.3 with

CNC software 4.7 SP4 or with HMI Pro sl V04.05.03.04 or higher for operating a SIMATIC CPU 317 / 319.

SINUMERIK Operate for PCU 50 does not include any technology cycles or measurement and ISO cycles.

These are available on the CF card of the NCU, and are automatically installed when the NCU powers up - also

see the notes provided in the upgrade instructions for the CNC software 4.7 SP4.

Installation

Important: A previously installed version V4.7 SP4 or higher of the SINUMERIK Operate for PCU 50 must first be

uninstalled under Control Panel / Programs and Features.

To install SINUMERIK Operate for PCU 50, the user must call the Setup_HMIsl_......exe file from the Windows

desktop of the PCU 50. To do this, either create a network connection to a PC using the DVD supplied or copy

the software from the DVD supplied to a USB flash drive and then connect it directly to the PCU 50.

The installation directory is permanently defined as C:Program Files (x86) for PCU 50 Windows 7 or F:hmisl for

PCU 50 WinXP.

During the installation, you will be asked about the installation type:

Operation on a SINUMERIK NCU (default setting)

Operation on a SIMATIC CPU 317 / 319

Integration of .NET-Framework for OEM applications

Licensing

For operation on an NCU, SINUMERIK Operate on PCU 50 requires licensing via the SINUMERIK option

6FC5800-0AP88-0YB0.

====================================================================

Compatibility

====================================================================

SINUMERIK Operate 4.7 SP4 can be combined with 840D sl NCU 7x0.3 (B) with CNC-SW 4.7 SP4.

The help system is based on the documentation for CNC SW 4.7 SP2.

NC alarm texts are based on CNC SW 4.7 SP2.

The additional languages V4.5.2 , V4.7.2.1 and V4.7.3 can be used. New texts in SW 4.7 SP4 are displayed

in English if drive texts (alarm and parameter texts as well as the corresponding online helps)

are also displayed in English when using the additional languages V4.5.2 and V4.7.2.1.

STEP7 for SINUMERIK PCU 50 from V5.5 SP3 and higher can be linked into SINUMERIK Operate 4.7 SP4

and can then be run.

Page 1 / 4Unrestricted / © Siemens AG 2016

SINUMERIK 840D sl

Upgrade instructions

SINUMERIK Operate 4.7 SP3 for PCU 50.5 / IPC

====================================================================

Notes regarding SINUMERIK Operate on PCU 50:

The "Local drive" in SINUMERIK Operate for PCU 50 Win7 is stored on the hard disk under C:Program

Files(x86)SiemensMotionControlusersinumerikdata and is always provided without option.

When using SIMATIC ITC panels, no touch softkey is available for the help function.

The mold and die view cannot be used with POLY and G91 blocks.

The mold and die view cannot be used with BSPLINE blocks.

Only the elements 0 to max. 65534 can be displayed or changed in GUD arrays, even if the array is

greater in the NC.

File/folder names that contain a minus character are rejected both in the NC memory and on the local

drive.

Restrictions with EES:

When using a USB stick on the TCU in combination with a PCU, you can currently not edit any files on

the USB with active EES mode. You can only execute these files.

If a USB stick on a TCU is accessed by several HMIs / NCUs in parallel, the components are not

coordinated. This entails the danger that a program being executed is modified / destroyed by another

component.

For the front USB of the TCU in combination with

If a specific user should be automatically logged on during installation of Operate on PCU 50 Win7, the

user must have a Windows wise the installation is aborted and fault Fehler 1722

output.

When installing Operate on PCU 50, the entered password is not checked with autologon set for a user.

When executing part programs from network drives or editing files on network drives, the user must

provide for a stable, interference-free network connection to the network drives.

When executing from USB stick it may occur that no program blocks are displayed if a USB stick was

inserted before into another USB interface.

When terminating Operate with the Exit softkey, an internal crash may occur which is not visible on the

operator interface. However, a Crashlog and a dump file are created in each case.

For touch panels without keyboard, the alarm screens of the Diagnostics area now include a vertical

softkey " Cancel Alarm".

R

softkey is displayed, the machine data MD 11280 $MN_WPD_INI_MODE must have the value 1.

OPC-UA:

There are two possibilities to set up a connection:

Connection without security

mode "SignAndEncry"

Siemens recommends that you always establish a connection with security, as only in this way the

confidentiality of the data transferred can be ensured.

When restarting Operate, it may occur that the reconnection with the OPC server fails. In this case, you

must restart NCU respectively PCU 50 / IPC.

Settings:

To operate a PCU 50 with an external monitor, the screen size of Operate can be set in the file

C:Program Files(x86) with the entry

[Global]

Page 2 / 4 Unrestricted / © Siemens AG 2016

SINUMERIK 840D sl

Upgrade instructions

SINUMERIK Operate 4.7 SP3 for PCU 50.5 / IPC

Resolution =; permissible values: 640x480, 800x600, 1024x768, 1280x1024

Subsequently enter Autostart of Operate for a (different) user on PCU 50.5-Win7:

On the desktop, start menu "All Programs", select Startup. Right-click and choose "Open". This opens an

Explorer. In the right-hand Explorer window, right-click and create "New" "Shortcut".

Then with "Browse ...", enter file "C:Program Files(x86)SiemensMotionControl siemenssinumerikhmi

".

Operate includes the "AppSight-Blackbox" (tool for analyzing causes of application crashes), and is active as

default. It can be deactivated by making an appropriate entry in file run_:

[BlackBox]

; enabled could be set to true or false. Default: true

enabled=true

The log file created by the AppSight Blackbox on error is called:

It is written when Operate is exited. Processes that are still running may need to be explicitly terminated.

This log file must be forwarded to the SINUMERIK Hotline together with the HMI crash log.

With Operate on PCU 50-WinXP the setting of the date / time only affects the clock of the NC/PLC, not the

clock of the PCU 50

New design

softkeys incl. the icons on the softkeys, the appearance of the window title bars, various colors (window

background colors) and the appearance / behavior of the header the displays for the operating area and

operating mode can be found on the right side of the header line and, with no alarm pending, the header

only shows the Siemens logo.

The new skin can be activated with the display MD 9112 HMI_SKIN = 1. After a restart, Operate uses the

new skin. For the new design, we recommend that you use a color depth of 32 bit.

With multi-touch operation (e.g. OP015Black) the functions of the user interface have also been expanded.

There are six function keys above the vertical softkeys which are always visible for the functions Undo,

Redo, Open/close online help, Open/close virtual keyboard, Open/close calculator, Create screenshot.

Page 2 / 4 Unrestricted / © Siemens AG 2016